HEAT RETURN

Your heat bill is an asset.

Compute runs hot and has to send its heat somewhere. Set what you burn today and see how much of it a modular compute site on your land could return, at your temperature.

Plants above 20 MW of thermal input are usually in the EU emissions trading system already; there the allowance price applies instead of ETS2. Set it in your gas price. On the live site this is prefilled from your connection. Is the plant in the EU emissions trading system?
Outside the EU ETS the ETS2 carbon price on heating fuels applies from 2028; the result counts it at €45 a tonne.
50% of your heat, returned
€0 to €68k net saving a year, low to high case
650 t CO₂ a year from gas no longer burned
450 kW of compute · gas cost replaced €227k a year
STEP 1 What you run
Brewing water, mash, cleaning and bottle washing sit below 95 °C. Wort boiling stays on your boiler.
STEP 2
6,500 MWh €455k a year at €70/MWh
300 MWh 500,000 MWh
The MWh figure is on your gas invoice. 1,000 MWh is roughly 94,000 m³. Small sites count too: the low end of the slider is a workshop or a small plant.
STEP 3 Temperature your heat is used at
Steam or boiling stays on your boiler. We count 60% of your heat as reachable below 95 °C.
STEP 4 When you need it
STEP 5 Where would the compute's power come from?
Counted at 6,500 run hours a year: on grid power the compute runs in the cheaper hours, so the heat follows those hours.
STEP 6
€70/MWh delivered, before VAT
Reference: TTF front month €86/MWh on 15 Oct 2026, as reported by oEnergetice.cz; contracts for 2027 at €72 and for 2028 at €46. The saving is counted at a term price of €70/MWh delivered, a draft figure; set your own above. If you make heat another way, enter the fuel cost you would stop paying.
STEP 7
€105/MWh delivered, before VAT
Used for the low case only: the temperature lift stage uses electricity, about a sixth to a quarter of the heat it delivers, charged here at a quarter. Default €105/MWh.
STEP 8 Solar, wind or an engine on site with power to spare?
Many sites have solar on the roof or an engine. If some of its output is spare in some hours, compute can pay for it.
STEP 9 Battery on site
A battery on site changes how spare hours are used. It carries no figure here; the site model counts it.
50% of your heat, returned
€0 to €68k net saving a year, low to high case
650 t CO₂ a year from gas no longer burned
450 kW of compute · gas cost replaced €227k a year
RESULT · YOUR HEAT ACCOUNT, PER YEAR
Heat returned to you 2,920 MWh · 50% of your heat
Gas you stop burning 3,240 MWh of gas
Gas cost you stop paying €227k
Heat you buy instead, at 30% below gas €159k
Net saving, if the heat price is your only cost €68k
Net saving, if you also pay the lift stage's electricity at €105/MWh €0
From 2028: ETS2 carbon cost you also avoid €29k
CO₂ from gas no longer burned 650 t
CO₂ from the gas no longer burned, at 0.202 t per MWh. A gross figure: the electricity the compute and the lift stage use is not netted off. An estimate, not a measured or verified reduction, and not a carbon credit.
Heat price below your gas cost DRAFT TERM
High case: the heat price is your only cost. Low case: you also pay the lift stage's electricity at your power price. Which case applies is worked out in the site model; terms are agreed only in signed agreements. Your boiler stays for peaks and backup.
WHAT SITS ON YOUR SITE
450 kW of compute, in containers or indoors About 15 m² if indoors, plus space for the temperature lift stage. Grid connection of about 560 kW, typically metered separately.
Compute 450 kW of liquid-cooled compute in closed enclosures. In containers or indoors.
Water loop · 55 to 65 °C out, 45 °C back
Heat exchanger Keeps the compute loop separate from your system. Typically up to 60 °C on your side.
Up to 60 °C into the lift stage
Temperature lift stage Sized to the compute heat; the technology is chosen in the site model. Uses about 70 kW to 110 kW of electricity and delivers about 470 kW into your temperature band.
Into your band below 95 °C
Your process Brewing water, mash, cleaning and bottle washing sit below 95 °C. Wort boiling stays on your boiler.
How we count

Per MW of connection, liquid-cooled compute draws about 0.93 MW and returns about 0.8 MW of heat at 55 to 65 °C, 8,000 hours a year on your own power and 6,500 on grid power. Above 60 °C a temperature lift stage raises it into your band; it uses electricity, about a sixth to a quarter of the heat it delivers (from a 65 or a 55 °C source), which the low case charges at your power price, at a quarter, and the high case does not. Compute is sized to your base load: 70% of annual heat when demand runs all year, 40% when it peaks in cold months. Boiler 90% efficient. 0.202 t CO₂ per MWh of gas. ETS2 from 2028, counted at €45 per tonne, the level (in 2020 prices) at which the EU releases reserve allowances; the market price may be higher. Shown only for EU sites outside the EU ETS: plants above 20 MW of thermal input are usually in the EU emissions trading system already, where the allowance price applies instead, set in your gas price; the district heating preset and a gas use of 100 GWh a year or more count as such a plant. Spare power on site: the compute takes it in the hours it is spare, up to its own draw, and pays €30 (low) to €45 (high) per MWh all-in, the same draft term as the spare power calculator; your gain is the part above what that power earns you today. A battery is counted in the site model, not here. Draft figures, rounded. Equipment, who supplies it and the terms are worked out in the site model and agreed only in signed agreements.

SEND THIS HEAT PLAN

Have your heat plan checked within 5 working days

We receive your inputs and the account above as one summary. We come back with what a site visit would check, for the compute and for the heat stage, and how the terms are usually structured.

Czechia Brewery Gas 6,500 MWh a year €70/MWh Heat, part above 95 °C Year-round Grid power Returns 50% of heat Net €0 to €68k a year at 30%
We use your name, email, company and the figures you send to reply to you, as set out in our Privacy Policy.
WHO IT IS FOR

Sites that heat water or run processes below 95 °C on gas: breweries, dairies, food plants, greenhouses, pools, hotels, laundries and district heating.

WHAT YOU CAN PROVIDE
  • Gas you burn for heat in a year, in MWh, from your bills
  • The temperature you use the heat at
  • Your gas price, before VAT
  • Whether compute would run on grid power or your own
WHAT YOU GET

How much of your heat compute could return, the net saving a year on a low and a high case, and the CO₂ you would no longer emit.